A SAP calculation for an extension is a energy model that shows your new space, together with the existing house, meets the energy rules in Part L of the Building Regulations. You do not need one for every extension. You need one when your design cannot follow the simple fixed-specification route, most often because of large areas of glazing. If that is your plan, we produce SAP calculations for extensions across London, and you can start from our SAP calculations page.
TL;DR
- A simple extension can often comply by meeting set U-values (heat-loss limits) and a glazing cap, with no SAP calculation.
- Large glazing, such as a glass rear extension or bi-fold doors, usually pushes a project onto the SAP route.
- The assessor models your extension against a notional version and needs your drawings and specification first.
- Published fee guides put SAP work for an extension at a few hundred pounds, with timing depending on how complete your drawings are.
- Rules change on 24 March 2027 in England, so check which edition applies to your Building Control application.
Table of Contents
- What a SAP calculation does for an extension
- Do you actually need a SAP calculation?
- What information the assessor needs
- The process from design to completion
- What a SAP calculation for an extension costs
- How long it takes
- What changes in England from March 2027
- Our view as assessors
- Get your extension’s SAP calculation
- FAQ
- Sources
What a SAP calculation does for an extension
SAP stands for the Standard Assessment Procedure. GOV.UK describes two main uses: showing that new homes comply with Part L of the Building Regulations, and producing Energy Performance Certificates. For an extension, the first use is the one that matters.
The assessor builds a digital model of your home with the proposed extension. Homebuilding explains that for extensions this is compared with a notional version capped at 25% glazing and built to the Building Regulations specification. If your design produces no higher CO2 emissions than that notional version, Building Control can accept it.
The point is flexibility. Glazing loses more heat than a wall, which is why the cap exists. A SAP calculation lets you keep a large glass elevation, provided you make up the difference elsewhere: better insulation, better windows, a more efficient heating system or renewables.

Do you actually need a SAP calculation?
The official guidance, Approved Document L Volume 1 (2026 edition), offers more than one way to show an extension complies. Broadly:
- The elemental route. Every new element meets a limiting U-value. A U-value measures heat loss through a surface, and lower is better. The guidance lists a maximum of 0.15 W/(m²·K) for a roof and 0.18 for a wall and for a floor. Windows and doors must also meet their limits, and the glazing area must stay within the cap. One technical summary gives 1.4 W/m²K for windows and a 25% cap on openings under the 2021 rules.
- The notional extension route. The guidance describes a notional extension of the same size and shape as yours that complies with the elemental route. Your extension must perform no worse. This needs a SAP calculation.
- Other routes. The guidance also covers whole-dwelling approaches and small-extension provisions, such as the floor-area limit it sets for some work. Your Building Control body will tell you if one applies.
In practice, a modest brick-and-block rear extension with standard windows can usually follow route 1. A kitchen extension with a wall of glass, roof lights and sliding doors rarely can. That is the moment to ask for a SAP calculation, ideally before the architect finalises the elevations.
Signs your extension will need one
- Glazing and doors take up more than about a quarter of the extension’s floor area.
- You want a large roof lantern or a fully glazed elevation.
- Your designer cannot reach the limiting U-values because of structural or space constraints, such as a thin roof build-up.
- Your Building Control body or architect has asked for “L1B” or Part L compliance calculations.
If you are unsure, send us your drawings and we will tell you which route fits.
What information the assessor needs
The quality of a SAP calculation depends on the quality of the inputs. According to Homebuilding’s guide, the assessor typically needs:
- Construction drawings and a site plan
- A project specification
- Insulation types and thicknesses, with U-values
- Window and door U-values and coatings
- Thermal bridging details (the junctions where heat escapes more easily)
- Target airtightness
- Heating and hot water details, lighting, ventilation and any renewables
Gather these before you ask for a quote. Missing details are the main cause of delay, and changing the specification after the calculation is done means the model has to be rerun.
A common trap: default thermal bridging
Builder Expert’s guide to Part L warns that default thermal bridging values carry a heavy penalty in SAP. That penalty then has to be recovered with thicker insulation, better glazing or more renewables. Specifying the actual junction details early usually gives the design more room.
The process from design to completion
For a London extension needing SAP, the sequence normally looks like this:
- Design-stage calculation. Based on your drawings, it shows the proposal can comply. It goes to Building Control with your building notice or full plans application.
- Build to the specification. Keep photographs of insulation and junctions as you build. Your builder must install what the calculation assumed.
- Testing and commissioning. Where the calculation relies on an airtightness target, an air pressure test may be needed.
- As-built calculation. Homebuilding notes that the assessment is repeated with the actual equipment and airtightness result. Builder Expert’s guide adds that the EPC is lodged before occupation for new dwellings.
- Completion certificate. Building Control issues it once the evidence is in.
Where you are adding to an existing home rather than building a new dwelling, your Building Control body confirms which of these steps apply. If a calculation shows the design just misses, we recommend changes to insulation, glazing or heating before you build, which costs far less than fixing it on site.
What a SAP calculation for an extension costs
Fees depend on the size and complexity of the project, so published figures are a guide only. Homebuilding puts SAP calculations for a large detached house, extension or conversion at around £200 to £400, as of its March 2024 update. Builder Expert’s Part L guide, updated in November 2026, lists design-stage and as-built SAP including the EPC at £150 to £450, with thermal bridging calculations for a set of junctions at £250 to £600 and an air pressure test at £150 to £350. You can also see typical SAP and EPC fees set out for new-build compliance.

Budget for the whole chain, not only the calculation: Building Control fees, testing and any specification upgrades the calculation calls for. For a quote on your own project, contact us with your drawings. Our claim is a UK lowest-rate guarantee, so it is worth sending us any quote you already hold.
How long it takes
The time depends on how complete your drawings and specification are. When the information arrives in one go, a design-stage calculation is usually a matter of days to a couple of weeks. Delays tend to come from waiting on window specifications, insulation choices or the heating design. Ask for the calculation before you submit to Building Control, not after, because a failed design needs reworking and resubmitting.
What changes in England from March 2027
The rules are moving, and the date you apply to Building Control matters.
- SAP 10.3 was approved on 24 March 2026, according to the official notice of approval.
- The same notice says earlier methodologies may continue for ordinary work if a building notice or initial notice is given, or full plans are deposited, before 24 March 2027, and work starts before 24 March 2028.
- GOV.UK’s SAP page, updated 8 June 2026, says the Home Energy Model launch has been delayed and SAP 10.3 is currently the only approved methodology.
If your extension is at design stage now, ask your assessor which edition of Part L and which SAP version your application falls under. We work to the version your application requires.
Our view as assessors
Most people meet SAP late, when Building Control asks for it and the drawings are already signed off. That is the expensive way round.
The calculation is a design tool. Run early, it tells you whether the glass wall you want will pass, and which small changes, a better roof build-up or a different window specification, will make it pass. Run late, it only tells you that you have a problem.
We assess extensions across London, and our advice is always the same: send us the drawings and specification before you submit. We will tell you which route applies, what the model needs, and what to change if the design falls short. We also deal with the related reports a project can need, such as overheating analysis and water calculations, so you do not have to coordinate several people.
Danny
Get your extension’s SAP calculation
We provide SAP calculations for new builds, conversions and extensions across London, with qualified assessors and our UK lowest-rate guarantee. Send us your drawings and specification and we will confirm what your project needs. Start at our SAP calculations page.

If your project also involves a larger scheme, we offer energy statements for planning and overheating assessments. For the finished property, a domestic EPC records the result.
FAQ
Why do I need a SAP calculation for an extension?
You need one when your design cannot meet the fixed elemental requirements, usually because of large glazing. The calculation shows Building Control that the extension performs no worse than a compliant notional version. Not every extension needs one.
How do you do a SAP calculation for an extension?
The assessor models your home and extension from your drawings and specification, then compares it with a notional extension. If your design produces no more CO2 than the notional version, it passes. If not, the specification is adjusted and rerun.
How much does a SAP calculation for an extension cost?
Published guides give ranges from around £150 to £450, depending on size and complexity. Thermal bridging calculations and air pressure tests are extra items. Send your drawings to us for a quote on your project.
Does the 2027 change affect my extension?
It can. Earlier methodologies may continue where a building notice or initial notice is given, or full plans are deposited, before 24 March 2027. Confirm the position with your Building Control body when you apply.
Sources
- Standard Assessment Procedure, GOV.UK
- Approved Document L Volume 1 Dwellings, 2026 edition
- Notice of approval of the methodologies of calculation, 24 March 2026
- SAP calculations: a guide, Homebuilding
- Part L Building Regulations 2026: Builder’s Guide
- Part L reference summary
- Typical SAP and EPC fees